 | ::: | - Power light ON \\ - indicator PUMP light ON \\ - Pump always OFF|Pump fuse burned |Replace the pump fuse | | ::: | - Power light ON \\ - indicator PUMP light ON \\ - Pump always OFF|Pump fuse burned |Replace the pump fuse |
 | Starts and stops continuously | Light indicators FULL and PUMP alternate| Defective high-pressure sensor or check valve|Change pressure sensor and check valve| | Starts and stops continuously | Light indicators FULL and PUMP alternate| Defective high-pressure sensor or check valve|Change pressure sensor and check valve|
-|Lack of pressure on water output| - Power light ON  | Watertank hand valve closed|Turn ON the watertank hand valve|+|Lack of pressure on purified ​water output| - Power light ON  | Watertank hand valve closed|Turn ON the watertank hand valve|
 | ::: | ::: | Requested pure water volume above the capacity of the water purifier|Wait the watertank is filled again\\ | | ::: | ::: | Requested pure water volume above the capacity of the water purifier|Wait the watertank is filled again\\ |
 | ::: | ::: | Lack of pressure in the pressurised watertank|Re-adjust the air-pressure of the water tank| | ::: | ::: | Lack of pressure in the pressurised watertank|Re-adjust the air-pressure of the water tank|