 ===== Troubleshooting ===== ===== Troubleshooting =====
-|**PROBLEMS**|**POTENTIAL CAUSES **|**SUGGESTED ACTION **| +|**PROBLEM**|**CONDITION**|**POTENTIAL CAUSES **|**SUGGESTED ACTION **| 
-| Power light  OFF|No power supply|Verify the power supply wires ; switch ​power ON | +| Water purifier OFF| Power light OFF|No power supply|Verify the power supply wires \\ - Switch ​power ON | 
-| ::: | Power supply fuse is broken| Check and replace the fuse| +| ::: | ::: | Power supply fuse is broken| Check and replace the fuse| 
-  ​- Power light  ON  ​- No production of purified water   - indicator PUMP is off  - indicator SOURCE is ON| The inlet tap water supply is closed or has insufficient pressure|Improve water supply| +|No production of purified water|- Power light  ON  ​\\ - indicator PUMP is off \\ - indicator SOURCE is ON| The inlet tap water supply is closed or has insufficient pressure|Improve water supply| 
-| ::: | Water inlet tubing folded or obstructed|Check that the inlet pipe is not damaged.| +| ::: | ::: | Water inlet tubing folded or obstructed|Check that the inlet pipe is not damaged.| 
-  ​- Power light  ON  ​- No production of purified water  ​- all control light indicators OFF|A fuse is broken :\\ - pump fuse \\ - fuse in the controller box| Check and replace the fuse| +::: |- Power light  ON  ​\\ - all control light indicators OFF|Fuse in the controller box broken ​Replace ​fuse | 
-  ​- Power light  ON  ​- No or low purified water production  ​- indicator PUMP light ON  - Pump running|Pre-treatment clogged| Replace the pre-treatment filters before the RO membrane| +|reduced flow of purified water|- Power light  ON  ​\\ - indicator PUMP light ON  ​\\ - Pump running ​continuously|Pre-treatment clogged| Replace the pre-treatment filters before the RO membrane| 
-| ::: | Weak flow of inlet water|Increase the flow of the inlet water| +::: |  ​::: | Weak flow of inlet water|Increase the flow of the inlet water| 
-| ::: |Reverse osmosis membrane clogged|Change the membrane | +| ::: | ::: | Reverse osmosis membrane clogged|Change the membrane | 
-  ​- Power light ON  - No or low purified water production  ​- indicator PUMP light ON  - Pump always OFF|Pump fuse burned |Replace the pump fuse | +::: |Pump leakage | Pump damaged|Replace the pump | 
-| Light indicators FULL and PUMP alternate|Defective high-pressure sensor or check valve|Change pressure sensor and check valve| +| ::: | ::: | Flow restrictor blocked| Replace flow restrictor | 
-  ​- Power light ON  ​- Lack of pressure and low  flow output| Watertank hand valve closed|Turn ON the watertank hand valve| +| ::: | - Power light ON \\ - indicator PUMP light ON \\ - Pump always OFF|Pump fuse burned |Replace the pump fuse | 
-| ::: |Requested pure water volume above the capacity of the water purifier|Wait the watertank is filled again\\ | +| Starts and stops continuously ​| Light indicators FULL and PUMP alternate| Defective high-pressure sensor or check valve|Change pressure sensor and check valve| 
-| ::: |Lack of pressure in the pressurised watertank|Re-adjust the air-pressure of the water tank| +|Lack of pressure on purified water output| ​- Power light ON  | Watertank hand valve closed|Turn ON the watertank hand valve| 
-| purified water conductivity too high|Resin saturated| Replace resin cartridge or bottle| +| ::: | ::: | Requested pure water volume above the capacity of the water purifier|Wait the watertank is filled again\\ | 
-  ​- POWER light ON  - FULL indicator ON  - Pump OFF  - Drain flowing continuously ​| Inlet solenoid valve defective|Replace the inlet solenoid valve| +| ::: | ::: | Lack of pressure in the pressurised watertank|Re-adjust the air-pressure of the water tank| 
-| Conductivity meter display OFF| Batteries out of order| Replace the batteries|+|purified water conductivity too high|   |Resin saturated| Replace resin cartridge or bottle| 
 +|Drain flowing continuously| ​- POWER light ON  ​\\ - FULL indicator ON  ​\\ - Pump indicator ​OFF   ​| Inlet solenoid valve defective|Replace the inlet solenoid valve| 
 +| ::: | - Power light ON   \\ - Pump indicator ON \\ - Auto-Flush not activated | Flush solenoid valve defective|Replace the flush solenoid valve| 
 +| Conductivity meter display OFF|  ​| Batteries out of order| Replace the batteries|
  