Line 45: Line 45:
 |No production of purified water|- Power light  ON  \\ - indicator PUMP is off \\ - indicator SOURCE is ON| The inlet tap water supply is closed or has insufficient pressure|Improve water supply| |No production of purified water|- Power light  ON  \\ - indicator PUMP is off \\ - indicator SOURCE is ON| The inlet tap water supply is closed or has insufficient pressure|Improve water supply|
 | ::: | ::: | Water inlet tubing folded or obstructed|Check that the inlet pipe is not damaged.| | ::: | ::: | Water inlet tubing folded or obstructed|Check that the inlet pipe is not damaged.|
-| ::: |- Power light  ON  \\ - all control light indicators OFF|A fuse is broken :\\ - pump fuse \\ - fuse in the controller box| Check and replace the fuse| +| ::: |- Power light  ON  \\ - all control light indicators OFF|Fuse in the controller box broken ​Replace ​fuse | 
-|Weak purified water production|- Power light  ON  \\ - indicator PUMP light ON  \\ - Pump running|Pre-treatment clogged| Replace the pre-treatment filters before the RO membrane|+|reduced flow of purified water|- Power light  ON  \\ - indicator PUMP light ON  \\ - Pump running ​continuously|Pre-treatment clogged| Replace the pre-treatment filters before the RO membrane|
 | ::: |  ::: | Weak flow of inlet water|Increase the flow of the inlet water| | ::: |  ::: | Weak flow of inlet water|Increase the flow of the inlet water|
 | ::: | ::: | Reverse osmosis membrane clogged|Change the membrane | | ::: | ::: | Reverse osmosis membrane clogged|Change the membrane |
 +| ::: |Pump leakage | Pump damaged|Replace the pump |
 +| ::: | ::: | Flow restrictor blocked| Replace flow restrictor |
 | ::: | - Power light ON \\ - indicator PUMP light ON \\ - Pump always OFF|Pump fuse burned |Replace the pump fuse | | ::: | - Power light ON \\ - indicator PUMP light ON \\ - Pump always OFF|Pump fuse burned |Replace the pump fuse |
-| ::: | - Power light ON \\ - indicator PUMP light OFF \\ - Water output hand valve opened|High pressure switch blocked |- Adjust the screw of the high pressure switch ​ \\ - Replace the high pressure switch | 
 | Starts and stops continuously | Light indicators FULL and PUMP alternate| Defective high-pressure sensor or check valve|Change pressure sensor and check valve| | Starts and stops continuously | Light indicators FULL and PUMP alternate| Defective high-pressure sensor or check valve|Change pressure sensor and check valve|
-|Lack of pressure on water output| - Power light ON  | Watertank hand valve closed|Turn ON the watertank hand valve|+|Lack of pressure on purified ​water output| - Power light ON  | Watertank hand valve closed|Turn ON the watertank hand valve|
 | ::: | ::: | Requested pure water volume above the capacity of the water purifier|Wait the watertank is filled again\\ | | ::: | ::: | Requested pure water volume above the capacity of the water purifier|Wait the watertank is filled again\\ |
 | ::: | ::: | Lack of pressure in the pressurised watertank|Re-adjust the air-pressure of the water tank| | ::: | ::: | Lack of pressure in the pressurised watertank|Re-adjust the air-pressure of the water tank|