Membrane replacement test

  • Measure the conductivity after the reverse osmosis membrane
  • Measure the conductivity of the tap water
  • Do the following calculation : 100 * (conductivity reverse osmosis) / (conductivity raw water)
  • If the value is less than 10%, the membrane is still usable

In the other case, the reverse osmosis membrane begins to saturate.