whenreplacingmembrane [2019/03/27 10:10]
thierry created
whenreplacingmembrane [2019/03/27 10:12] (current)
thierry
Line 1: Line 1:
 ====== Membrane replacement test ====== ====== Membrane replacement test ======
  
-Do the following calculation ​to get a percentage: +  * Measure the conductivity after the reverse osmosis membrane 
-100 * (TDS reverse osmosis) / (TDS raw water) ​= x%+  * Measure the conductivity of the tap water 
 +  * Do the following calculation : 100 * (conductivity ​reverse osmosis) / (conductivity ​raw water) ​ 
 +  * If the value is less **than 10%**, the membrane is still usable
  
-If the value is less **than 10%**, the membrane is still usable. ​ 
 In the other case,  the reverse osmosis membrane begins to saturate. In the other case,  the reverse osmosis membrane begins to saturate.
    