 ====== Membrane replacement test ====== ====== Membrane replacement test ======
  
-Measure the conductivity after the reverse osmosis membrane +  * Measure the conductivity after the reverse osmosis membrane 
-Measure the conductivity of the tap water +  ​* ​Measure the conductivity of the tap water 
-Do the following calculation : 100 * (conductivity reverse osmosis) / (conductivity raw water) ​+  ​* ​Do the following calculation : 100 * (conductivity reverse osmosis) / (conductivity raw water) ​ 
 +  * If the value is less **than 10%**, the membrane is still usable
  
-If the value is less **than 10%**, the membrane is still usable. ​ 
 In the other case,  the reverse osmosis membrane begins to saturate. In the other case,  the reverse osmosis membrane begins to saturate.
    